Element 6 (Radiotelegraph)A short in the armature coils of a DC motor causes:
Explanation
A short in the armature coils bypasses some windings, effectively reducing the number of active turns. This significantly decreases the back Electromotive Force (EMF) generated by the motor for a given speed. Since back EMF opposes the applied voltage, a lower back EMF means a higher net voltage across the armature. This results in excessive armature current.
Excessive current causes increased I²R losses, leading to significant overheating of the motor (making option B incorrect). It also causes excessive sparking at the commutator brushes (making option A incorrect). The high current, combined with the reduced effective turns, diminishes the motor's ability to produce sufficient torque, leading to a reduction of speed, especially when operating under load. Therefore, option C is correct.
Related Questions
6A331 When the field of a shunt-wound DC motor opens while the machine is operating under no load:6A332 ____ are used in a DC motor to reduce brush sparking without moving the brushes:6A334 The motor-field rheostat should be ____ when starting a DC motor generator set:6A335 If a motor generator fails to start when the start button is depressed, the trouble may be:6A336 When increased output is desired from a motor-generator, what is the usual procedure?